Pentek Intellidrive Troubleshooting Guide

Pentek Intellidrive Troubleshooting Guide Verify installation Make sure that the system has properly sized pressure relief valve and Table 9 lists all available commands and pressure tank parameters for the PENTEK INTELLIDRIVE Make sure pressure tank s precharge is correct See Table 7 Make sure pump discharge is connected to system

Need a helping hand Our knowledgeable customer service representatives are ready to assist you Find A Dealer Connect with a Pentair dealer near you App tech support for the Pentek Intellidrive smart connected device Find product resources and Pentair App FAQs Before doing any service or maintenance inside Drive or when connecting or disconnecting any wires inside Drive 1 DISCONNECT power 2 WAIT 5 minutes for retained voltage to discharge 3 Open box Before starting any wiring or inspection procedures check for residual voltage with a voltage tester

Pentek Intellidrive Troubleshooting Guide

franklin-electric-franklin-electric-3200-series-7fr07s4-pePentek Intellidrive Troubleshooting Guide
http://www.rcworst.com/Shared/content/mfr/franklin_electric/product_imgs/fec3200seriespe_001_wbg.jpg

Welcome to your new Pentek Intellidrive XL Please review the following information to setup your drive for constant pressure applications For further information please reference the Danfos Design Guide for VLT AQUA Drive FC 202 130R0337 and the Danfoss Programming Guide for VLT AQUA Drive FC 202 130R0338 Safety Hazardous voltage

Pre-crafted templates use a time-saving service for developing a varied variety of files and files. These pre-designed formats and designs can be used for different individual and expert tasks, including resumes, invites, flyers, newsletters, reports, presentations, and more, enhancing the content creation procedure.

Pentek Intellidrive Troubleshooting Guide

pentek-pentek-150435-clear-water-filter-housing-10-w-pr-3-4-ptk150435

Pentek Pentek 150435 Clear Water Filter Housing 10 W PR 3 4 PTK150435

pentek-150337-pentair-bag-filter-housing-r-c-worst-co

Pentek 150337 Pentair Bag Filter Housing R C Worst Co

franklin-electric-franklin-electric-425ssi60f86-0865-8-inch-ssi

Franklin Electric Franklin Electric 425SSI60F86 0865 8 Inch SSI

pentair-pentair-pentek-intellidrive-pid-variable-frequency-drive

Pentair Pentair Pentek Intellidrive PID Variable Frequency Drive

flint-walling-flint-walling-cj101b201ab-cj101-multi-stage

Flint Walling Flint Walling CJ101B201AB CJ101 Multi Stage

barmesa-pumps-barmesa-hmv22-90-403-vertical-multi-stage-centrifugal

Barmesa Pumps Barmesa HMV22 90 403 Vertical Multi Stage Centrifugal

Franklin Electric Franklin Electric 3200 Series 7FR07S4 PE
span class result type

https://www.pumpsystems.ca/_docs/_specialty-products/intellidrive_troubleshooting_guide.pdf
Read the Owner s Manual and related documentation carefully before attempting to operate the PENTEK INTELLIDRIVETM Make sure that you have a full knowledge of the equipment safety infor mation and instructions before using this product

Myers Myers N512R 01 Rustler Series 4 Submersible Well Pump End 12
span class result type

https://www.pentair.com/content/dam/extranet/web/nam/pentek/faqs/PENTEK_INTELLIDRIVE_FAQ.pdf
1 Do I have to ground the motor and the incoming power 2 The display shows a much lower pressure when the pump is running than when it is stopped 3 I want to use Brand X 250PSI transducer How do I 4 I want to increase the pressure setpoint to above 100 psi How do I do this 5

Myers Myers SMC CRP5021 NEMA 3R Pentek Submersible Motor Controls 5 0
span class result type

https://www.pentair.com/content/dam/extranet/web/nam/pentek/manuals/pn1014-pentek-intellidrive-qsg.pdf
1a 1b 2 Remove cover from the drive Shut off the power to the drive Wait 5 minutes to allow capacitors to de energize Separate cover and back plate Verify there is a gap between cover and back plate Pull out bottom of cover and remove 3 Connect Pentek communication hub to the drive Locate the P and N terminals in the I O Connection area

Zoeller Zoeller Model G266 Sewage Effluent Or Dewatering Pump 0 5 HP
Pentair Pentek Intellidrive Series Owner s Manual

https://www.manualslib.com/manual/1781780/Pentair-Pentek-Intellidrive-Series.html
Troubleshooting Fault Possible Causes Solution Shorted output Check for any shorts in motor cables Over Current Damaged wire insulation Check motor wire insulation with a megger With power to Drive off measure outputs Internal Drive short with ohmmeter to detect short

Pentek Intellidrive Quick Start Guide YouTube
span class result type

https://www.preferredpump.com/wp-content/uploads/2017/05/Pentair-Intellidrive-IO-maual-PID10-20-and-50.pdf
The PENTEK INTELLIDRIVE is specifically designed to operate 4 submersible pumps and 3 phase above ground pumps in water well and residential booster applications Each Drive is rated for maximum output amp rating Any use of Drive outside of intended design parameters will void warranty


PENTEK INTELLIDRIVE Setup Guide will appear Enter Motor Phase in the display Follow 1 Phase or 3 Phase the keypress sequence Press Enter shown here 1 Phase Connection Type 2 Wire or 3 Wire Press Enter Continued next column Enter Service Factor Amps Press Enter 5 Set Time Initial Startup Check List Press Enter OWNER S MANUAL PENTEK INTELLIDRIVE Quick Start Guide Owner s Manual PENTEKINTELLIDRIVE Model Number Structure PIDXX Product Family PID PENTEK INTELLIDRIVE HP Range 10 up to 1 0 HP 20 up to 2 0 HP 30 up to 3 0 HP 50 up to 5 0 HP The PID10 will operate a 1 Phase 2 Wire 1 Phase

4 PN793 04 30 2023 ELECTRICAL SAFETY RISK OF ELECTRIC SHOCK Can shock burn or kill All wiring should be done by a qualified electrician Disconnect power before working on pump motor or tank Ground motor controls all metal pipe and accessories connected to the motor to the power supply ground