Dhs Synthes Technique Guide Synthes DHS DCS Basic Set One Step Insertion 105 831 Top Tray Catalog Description 338 01 Angle Guide 135 338 02 Angle Guide 140 338 03 Angle Guide 145 338 04 Angle Guide 150 338 44 DHS Reaming Head Short 338 13 DHS Triple Reamer Complete Includes Drill Bit 338 10 Reaming Head 338 11 and Locking Nut 338 12
338 044 LCP DHHS Angled Guide adjustable 338 000 DHS DCS Guide Wire B 2 5 mm with threaded tip with trocar length 230 mm or 900 723 Guide Wire B 2 5 mm with spade point tip length 230 mm Optional instrument 310 190 Drill Bit B 2 0 mm length 100 75 mm 2 flute Fracture reduction should be done in the same manner as A Cortex screws for the conventional DHS plate Instruments 323 460 Universal Drill Guide 4 5 3 2 310 310 Drill Bit 3 2 mm 319 010 Depth Gauge 314 150 Screwdriver Shaft hexagonal Use the drill guide and the drill bit to drill holes in a neutral position through the plate holes Insert self tapping 4 5 mm cortex screws of appropriate length
Dhs Synthes Technique Guide
Dhs Synthes Technique Guide
https://i.pinimg.com/originals/b7/29/02/b72902b8be3b47a782a029c682e1de4c.jpg
338 005 DHS Angled Guide 130 or 338 010 DHS Angled Guide 135 or 338 020 DHS Angled Guide 140 or 338 030 DHS Angled Guide 145 or 338 040 DHS Angled Guide 150 or 338 044 LCP DHHS Angled Guide adjustable 723900 Gduie We r i B 2 5 mm with spade point tip length 230 mm Align the appropriate DHS angle guide or the LCP DHHS
Pre-crafted templates provide a time-saving option for developing a varied range of documents and files. These pre-designed formats and designs can be made use of for numerous individual and professional projects, consisting of resumes, invitations, leaflets, newsletters, reports, discussions, and more, simplifying the material development process.
Dhs Synthes Technique Guide

Synthes DHS Basic Set

Synthes DHS DCS Impactor

Synthes DHS Universal Implant Set

Synthes DHS DCS Basic Set One Step Insertion

Synthes 105 35 Synthes DHS Universal Implant Complete Set ESutures
Synthes Dhs Technique Guide

http://synthes.vo.llnwd.net/o16/Mobile/Synthes%20International/KYO/Trauma/PDFs/036.000.255.pdf
This PDF document provides the surgical technique for the Dynamic Hip Screw DHS System a device for the fixation of proximal femoral fractures It covers the indications preoperative planning implant selection operative procedure and postoperative care The DHS System allows for controlled impaction and compression of the fracture site
https://www.manualslib.com/manual/1746377/Synthes-Dhs.html
DHS DCS Standard System DCS plate 95 The following surgical technique is illustrated using the example of a fracture of the distal femur The DCS plate 95 can also be used on the proximal femur using the same technique To determine the entry point on the proximal femur see step 4 page 13 Page 14 Determine entry point for the DHS DCS

http://www.wemed1.com/downloads/dl/file/id/7478/product/8170/technique_guide_for_synthes_dhs_implant_set_105_35.pdf
Surgical Technique DHS continued 8 Synthes DHS DCS Dynamic Hip and Condylar Screw System Technique Guide 3 Confirm placement Confirm placement of the 2 5 mm threaded guide wire under image intensification It must lie along the axis of the femoral neck in both the AP and lateral views and parallel to the anteversion wire

http://synthes.vo.llnwd.net/o16/LLNWMB8/US%20Mobile/Synthes%20North%20America/Product%20Support%20Materials/Technique%20Guides/103452913%20Rev%20E.pdf
Femoral Neck System FNS Surgical Technique DePuy Synthes 11 2 Option adjust guide wire Instruments 357 399 3 2 mm Guide Wire 400 mm 03 168 002 Correction Guide for 3 2 mm Guide Wires optional Use the correction guide and an unused guide wire to adjust the position of the central guide wire in reference to the initial central guide wire

https://www.jnjmedtech.com/en-EMEA/product/dhs-dcs-system
Simply fill out the details of your request and we will get back to you as soon as possible Other Enquiries For product details such as indications contraindications warnings and precautions please consult the IFU and Surgical Technique 107672 211216 The DHS DCS System includes a DHS Blade and Locking Trochanter Stabilization Plate LTSP
AONA Technique Guide Index The material presented by AO North America on this website is directed to orthopaedic surgeons neurosurgeons plastic and maxillofacial surgeons and veterinary surgeons in North America and is intended for educational and communication purposes only Generally for femoral neck fractures a two hole DHS plate is enough Barrel length A plate with a short barrel illustration on the right may be used if the lag screw length is 75 mm to allow for sliding A short barrel should only be considered if its end would impinge dense cancellous bone in the head Neck shaft angle
DePuy Synthes reusable devices instrument trays and cases as well as the guide wire Alternative Technique Instruments 03 037 008 Awl B 8 4 7 mm curved cannulated for Quick Coupling for DHS DCS 357 399 Guide Wire B 3 2 mm length 400 mm Using the protection sleeve and cannulated drill bit drill