Stryker Triathlon Technique Guide If desired the Support Arm Resection Guide Tower and IM Reamer can be removed before completing the tibial resections To do so depress the tabs on the Support Arm to disengage it from the Revision Tibial Resection Guide Slide the Support Arm anterior Depress the tab on the Resection Guide Tower and slide it off the IM Reamer
The Triathlon Total Knee System is a primary total knee replacement system designed to work with the body Triathlon has been implanted in over 3 million patients worldwide Triathlon Total Knee is available for use with the Mako System for Mako Total Knee Designed to work with the body The Triathlon Total Knee System beaded and beaded with Peri Apatite components are intended for uncemented use only Contraindications Any active or suspected latent infection in or about the knee joint Distant foci of infection which may cause hematogenous spread to the implant site
Stryker Triathlon Technique Guide
Stryker Triathlon Technique Guide
https://i.ytimg.com/vi/SEz8WnJcLlg/maxresdefault.jpg
Stryker Orthopaedics wishes to thank the entire Triathlon Universal Baseplate Surgeon Panel and the dozens of surgeons worldwide who guided the design and development of the Triathlon Universal Baseplate Instrumentation Introduction The Triathlon Knee System Instrumentation has been developed based on Stryker s 30 year orthopaedic history
Templates are pre-designed documents or files that can be utilized for different purposes. They can save time and effort by supplying a ready-made format and layout for creating various type of material. Templates can be utilized for individual or professional tasks, such as resumes, invites, leaflets, newsletters, reports, presentations, and more.
Stryker Triathlon Technique Guide

Stryker Trauma 5515 F 101 Stryker Triathlon Knee Posterior

Stryker triathlon knee with shapematch Consumer Safety Watch

Stryker Knee Triathlon Problems LIVESTRONG COM

Stryker Trauma 5532 G 216 Stryker Triathlon X3 PS Tibial Bearing

New Page 1 bonepit

Tekno Surgical Orthopaedics

https://www.strykermeded.com/media/2201/triathlon-tritanium-surgical-technique.pdf
Stryker Orthopaedics wishes to thank the global Triathlon Tritanium Knee System The Triathlon Total Knee System beaded and beaded with Peri Apatite components are intended for Guide is designed for use on either the left or right knee and may be set to 5 6 or 7 of valgus

https://www.strykermeded.com/media/2960/triath_sp_16-ssp-ca2098-triathlon-universal-baseplate-surgical-technique.pdf
Assembly Instructions Many of the Triathlon Knee System Instruments have mechanisms incorporated to assist surgeons and OR staff in a simplified efficient surgical experience
https://www.strykermeded.com/media/2957/trits-sp-2-ssp-ca1984-triathlon-revision-knee-system-surgical-technique.pdf
Assemble the Revision Tibial Resection Guide to the Support Arm Slide the assembly on to the Resection Guide Tower Set distal proximal resection level and rotation by depressing the finger tab on the Resection Guide Tower Use the Stop Plate or place the Blade Runner through the cutting slot to determine the resection level When

https://www.strykermeded.com/media/2047/triathlon-pkr-surgical-technique.pdf
Triathlon Partial Knee Resurfacing is a fixed bearing unicompartmental knee that blends the ease of a measured resection system with the control of a ligament tension restoring gap balancing system

https://www.manualslib.com/manual/1755625/Stryker-Triathlon-Knee-System.html
Related Manuals for Stryker Triathlon Knee System Medical Equipment Stryker T PUMP TP600 Operation Manual Localized temperature therapy system 79 pages Distal Resection to insert into the Distal Resection Guide The Triathlon Knee System Instruments are designed to provide control of the saw blade during bone resections When using
Triathlon Knee System and instrumentation Introduction The Triathlon Knee System Instrumentation has been developed based on Stryker s 30 year orthopaedic history The system combines the expertise of orthopaedic and human factors engineers with that of surgeons and O R staff worldwide The Stryker Triathlon Knee System Instrumentation features mechanisms that provide surgeons and OR Staff a more simplified and efficient surgical experience Assembly instructions are included in the first section of this surgical technique to assist with instruments that may be pre assembled on the back table as well as other
Stryker Orthopaedics wishes to thank the entireTriathlonUniversal Baseplate Surgeon Panel andthe dozens of surgeons worldwide who guided the design and development of the Triathlon Universal Baseplate Instrumentation Introduction The Triathlon Knee System Instrumentationhas beendeveloped basedon Stryker s 30 year orthopaedic history