Nec Disconnect Labeling Requirements What Has Changed for the 2020 NEC NEC Section 230 71 has undergone a significant overhaul for the 2020 Code cycle namely the omission of the previous permission to install six switches or sets of circuit breakers acting as service disconnect in a single enclosure
As noted in Sec 110 22 A each disconnect must be legibly marked to indicate its purpose unless located and arranged so the purpose is evident In other than one or two family dwellings the marking must include the identification of the circuit source that supplies the disconnecting means Code Q A NEC Requirements for Using and The six disconnect rule has been the requirement since the 1933 NEC for residences and the 1937 NEC for all occupancies The 2020 NEC made a dramatic change to 230 71 by stating in A that each service shall have only one disconnecting means unless the requirements in 230 71 B are met
Nec Disconnect Labeling Requirements
Nec Disconnect Labeling Requirements
https://www.badmonkeyelectric.com/wp-content/uploads/2021/07/outdoor-emergency-disconnects.jpg
For example where caution warning or danger labels are required the labels must meet three requirements Sec 110 21 B 1 The markings must warn of the hazards using effective words colors symbols or a combination of words colors and symbols 2 The label cannot be handwritten and it must be permanently affixed to the equipment 3
Pre-crafted templates use a time-saving service for producing a diverse variety of files and files. These pre-designed formats and designs can be used for various personal and professional jobs, including resumes, invites, flyers, newsletters, reports, discussions, and more, streamlining the material creation process.
Nec Disconnect Labeling Requirements

NEC Solar System Breaker Label VLT 13446 Electrical Alternative Energy

NEC Multisync M551 LANG IBERIA

NEC MultiSync E507Q Sharp NEC Display Solutions Education Website

NEC Disconnect Label VLT 13073 Electrical Warning

Code Q A Proper Marking Of Disconnects EC M

Solar Nec Code Tutorial Pics

https://e-hazard.com/nec-changes-part-1-what-is-required-on-an-electrical-disconnect-switch-label/
Anything beyond a visible conduit to a local load indicates a clear cut need for proper labeling of the disconnect The identification of the source that supplies the disconnecting means is a critical addition to the 2020 NEC For ALL disconnects the associated power supply must now be clearly indicated on a label that is legible and clear

https://iaeimagazine.org/2016/november2016/service-equipment-labeling-nec-2017-110-16b/
It has been separated into two first level sub divisions with the existing language that has been in the NEC since NEC 2002 retained as first level subdivision A General and a new labeling requirement is added in B Service Equipment

https://www.electricallicenserenewal.com/Electrical-Continuing-Education-Courses/NEC-Content.php?sectionID=799.0
General Click to Enlarge The 2020 NEC requires a disconnecting means to be marked to identify the source of supply Code Change Summary New requirement added to existing text For other than one or two family dwellings the 2020 NEC will require additional marking to identify where a disconnecting means is fed from

https://www.ecmweb.com/safety/article/20899009/the-ins-and-outs-of-electrical-labeling-part-1-of-2
In addition the service disconnect must also be labeled as the Service Disconnect per NEC 230 70 B Per the NEC you must also consider additional labeling if you have more than one service disconnect in your building If so you have to place an additional label that states the location of the other disconnect as per NEC 230 72 A

https://www.eaton.com/content/dam/eaton/products/residential/electrical-safety/electrical-safety-national-electrical-code-2020-br1610048en.pdf
Code changes based on the 2020 National Electrical Code Dwelling Unit Area Reference Chart for AFCI and GFCI Requirements 3 National Electrical CodeIntroduction 5 Electrical Connections 110 14 D Terminal Connection Torque 6 Ground Fault Circuit Interrupter Protection for Personnel 210 8 Preface 7 210 8 for Personnel 8
The NEC rules on to disconnecting means locations are designed to facilitate an electrically safe work condition The NEC rules work hand in hand with the requirements for achieving electrical safety as set forth in NFPA 70E Standard for Electrical Safety in the Workplace The NEC does not contain a general requirement to label service feeder and branch circuit conductors Section 110 22 A requires each disconnecting means to be legibly marked to indicate its purpose unless it is located and arranged so that the purpose of the disconnect is evident
Section 225 41 is new in the 2023 NEC and provides a new requirement to have an emergency disconnect for one and two family dwelling units supplied by an outside feeder or branch circuit similar to the requirements in Section 230 85 for services